On Center Home | MyOnCenter Portal | Start an On-Screen Takeoff Trial | Request a Quick Bid Demo | Contact Us | SALES: 1-866-627-6246
   
 
Learn more about Searching
Looking for help for one of ConstructConnect's Other products? Login


Tools
Table of Contents

Quick Bid - 05.07.04 The Item Details Calculations Tab: On Center Exception Factors - QB

Views: 532 Last Updated: 10/31/2024 07:34 am 0 Rating/ Voters
Be sure to rate this article 5 Stars if you find it helpful!

The Standard Formula isn't the only game in town when it comes to calculating Item Quantity.

Quick Bid Item Detail dialog box with Calculation tab open

On Center Exception Factors

On Center Exception Factors instruct Quick Bid to substitute the normal Calculation Method when the 'on center' measure equals one of two predefined values. When these fields are populated and the on center (OC) value for an Item used in a Condition Detail matches 16" or 24" (or 400/600 mm in a Metric database) the value specified in the Exception Factor is used to calculate Item quantity values instead of the selected Calculation Method. This option is disabled if "Continuous" Installation Method is selected and when the Calculation Method is not "Standard Formula" or "Quantity * Height".

The Exception Factor is expressed as a decimal value and when used, no Waste is applied to the calculated quantity. The Exception Factors provide the estimator with another option for adding waste according to a specific factor. This method allows a different waste factor (%) for materials defaulting to 16” OC or 24” OC. The Installation Method controls the application of the Exception Factors.

How Exception Factors work

Using the Standard Formula, Quick Bid calculates the quantity of a material as follows:

Wall Length x Wall Height ÷ OC x Layers + waste % = Item quantity

Using the Exception Factors set to 16” OC = .85 and 24” OC = .65 (these Exception Factors are examples only, not cast-in-concrete numbers or even suggestions), Quick Bid calculates the Item detail quantity as follows:

Wall length x Wall Height x Exception Factor x Layers = Item quantity

If the Exception Factors for 16” or 24” OC are used, Quick Bid ignores any value entered in the Waste % field when OC = 16 or 24. The OC is also not factored into the calculation as in the Standard Formula (for all intents and purposes, the Exception Factor replaces the "on center" (OC) value in the Standard Formula).

The Exception factors are applied only when the OC for a Condition Detail line Item equals 16” or 24” (Imperial) or 400mm or 600mm (Metric). If a line Item uses any other OC values, Quick Bid uses the specified Calculation Method and Waste % so it is important to maintain a Waste % value even when using the OC Exception Factor formula.

click here to view the previous article The Calculations tab: Installation Method Item Details - the Sizing Tab Overview and Video click here to view the next article

>


Product documentation (user guides) describes functionality in the latest version of each major release and may not match the functionality in the version you are using. Please check the Product Information and Downloads pages by clicking one of the product buttons above.

Something Wrong with this Article? Let us Know! The information in this site is protected by copyright by ConstructConnect. You may not reproduce, adapt, or publish any content from this site in whole or in part for any purpose, without the express written consent of ConstructConnect, Inc.
Copyright 2024 - All Rights Reserved.